Question 3: What determines number of stages of the progressing cavity pumps?
Answer:
Number of stages depends on several factors, with the main one is total differential pressure. Typically, a stage is added for each 75-100 psi. For example, a 300 psi differential would require 4-5 stages. Manufacturers catalog provides different curves for different stage number designs.